Role & seniority: Test Technician (entry- to mid-level)
Stack/tools: Electrical test equipment (impulse generator, Hi-Pot, motor generator, power factor test kit, SFRA set, BCT/Omicron test sets), meters (voltmeters, ammeters, wattmeters, ohmmeters), oscilloscopes, test laptops, VOMs; ability to read electrical prints and use manufacturer specs
Set up and perform electrical tests per blueprints, diagrams, and specifications to verify transformer controls, dielectric withstand, and thermal capability
Interpret test data, identify issues, write NCRs, troubleshoot, and prepare data/electronic reports and charts
Maintain/repair test equipment, perform final inspections and sign-off, and ensure safety and documentation during witness testing when required
Ability to read electrical prints and requirements; strong safety mindset and arc flash awareness
Experience configuring power supplies/generators, troubleshooting electrical problems
Comfortable performing high-voltage tests up to 1M V impulse, >400kV applied potential, and related tests; works with minimal supervision
Education: BSEE or equivalent, or relevant electrical training with several years of QA/testing experience
Experience with SFRA, BCT testing, Omicron test sets, oil quality/dew point/sound testing
Exposure to high-voltage transformer testing and witness testing
Location & work type: Prolec GE
What Does Prolec GE Waukesha Do?
JOB SUMMARY
To perform a broad variety of tests on equipment and manufactured parts to determine if engineering standards, customer specification & IEEE standards have been met. Prolec GE Waukesha produces primarily 3 phase power step down transformers.
PRINCIPLE DUTIES AND RESPONSIBILITIES
Primary operating voltages range from 69kV to 230kV. This position encompasses performing the electrical tests to 1) verify the transformer controls: gauge, instrument and programmable controller operation and 2) transformer dielectric withstand and thermal capability. The controls testing involves employing VOMs and laptop computers to test circuit logic, instrument functionality and performance characteristics. The dielectric testing involves impulse testing to 1M V, Applied Potential testing >400kV, 3 phase 240Hz induced testing >100kV and 3 phase 60Hz performance testing.
The test technician will follow blueprints, diagrams, downloads from manufacturer’s web-sites and engineering specifications to set up and perform various test on equipment, manufactured parts and power supplies.
Interprets test data, identifies technical problem solutions and writes NCRs for quality problems during their assigned shift as well as the off shift.
Makes repairs on assigned test equipment as needed.
Performs the necessary test calculations and prepare data electronically as listed below to confirm test are complete and have produced acceptable results:
*** NOTE:** Must be able to satisfactorily perform a minimum 2 of the Special tests. May perform test in the presence of customers or their representatives during Witness testing.
KNOWLEDGE, SKILLS & ABILITIES
TOOLS AND MACHINERY
Hand tools, ladders, electrical measuring meters, mechanical measuring devices, test equipment, system computer, and various computer controlled test equipment. Uses a variety of equipment to include impulse generator, Hi Pot, motor generator, power factor test kit, SFRA set, voltmeters, ammeters, watt meters, ohmmeters, bridges, oscilloscopes and wave analyzers to test a variety of equipment and manufactured parts.
MATERIALS
Arc flash clothing, electrically rated gloves
GENERAL
The successful candidate must be able to read electrical prints, technical requirements and industry standards. All testing parameters are predicated on the transformers design characteristics. The testing is not of the “plug in the wiring harness, push the start button and note the results” genre. It requires first and foremost a safety mindset as well as the ability to configure power supplies and generators and trouble shoot electrical problems. They must also obtain Arc flash training, follow safe electrical work practices, and take proper precautions to maintain arc flash boundaries for fellow testers and assemblers. Works under minimal supervision. Able to layout materials and setup for tasking. Work varies from working at ground level to working in, on top of, and around the sides of the unit, which may be 6 feet or more in height.
EDUCATION AND EXPERIENCE
A BSEE (or equivalent) is required with no experience, OR an AA degree in the electrical field with some related experience, OR high school diploma or GED with supplemental specialized electrical training and three years of experience OR high school diploma or GED plus 4 years of progressive experience in QA testing.
ADDITIONAL INFORMATION
The above description covers the principle functions of the job. It is not intended to be a complete listing of all the miscellaneous, incidental, or substantially similar duties, which may be assigned during normal or emergency operations.
Prolec-GE Waukesha, Inc. is an equal opportunity employer and makes employment decisions without regard to race, color, religion, national origin, sex, sexual orientation, gender identity, age, genetic information, disability, protected veteran status, or any other reason prohibited by applicable law.